SPECIFICATIONS
|
MODEL |
SC12ETC |
|
Power supply |
230V 50Hz |
|
Coolant |
R-407C |
|
Coolant capacity |
520 g |
|
Ventilation speeds |
3 |
|
Net weight |
32kgs |
|
Dimensions |
377 x 446 x 738 mm (W x D x H) |
BEFORE USE
|
Plug the unit directly into an earthed
electrical outlet and operate only at the recommended voltage. (Please refer
to the sticker on the back of the unit.) Do not use this unit for any other purpose
than those described in this owner’s manual. Always ensure that the unit stands vertically
on a flat, stable surface (FIG.1) Do not obstruct the air inlet and outlet
grilles. (FIG.2) Do not use the product in a humid room, such
as a bathroom or laundry room. (FIG.3) Position the unit at least 50cm from walls and
other obstructions (furniture, curtains….) (FIG.4) Do not put anything on top of the unit. Do not handle the unit with wet hands when
barefoot. Do not let chemical substances come into
contact with the unit. Do not use the unit near flammable substances
such as alcohol, insecticides, petrol etc. Do not turn off the unit at the socket. Always
use the ”ON/OFF” switch on the control panel. If unit is malfunctioning, always switch it
off and unplug it. Always switch off and unplug unit before
cleaning it. Watch children and pets while the unit is in
operation. They are unaware of the dangers posed by electrical applicances. |
|
-
If the electrical socket is different from the plug,
have a qualified electrician replace it with a suitable one. Avoid the use of
adaptors, multiple adaptors and / or extension cables. If you absolutely must
use them, ensure they conform to current safety regulations.
-
Do not pull the power cord or place it near a heat
source; always unwind it completely to avoid dangerous overheating.
- Should the power supply cable
become damaged, avoid any risk of danger by getting it replaced by a qualified
person.
- Never use the unit without
the filter.
-
Switch off and then unplug the unit when it is not in
use.
- This appliance should only be
used indoors.
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF
THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.
For maximum efficiency.
-
Do not locate air near furniture or other objects that
could obstruct airflow.
-
Keep blinds/curtains closed during the sunniest part
of the day.
-
Close or block chimneys and other passages so cool air
does not escape.
-
Keep the filters clean.
-
When you first turn on the unit, set it to maximum
speed and then adjust to the temperature desired.
PARTS
Front
Back

|
1-
Control Panel 2-
Cool Air Outlet 3-
Handle 4-
Casters |
5-
Air Filter 6-
Air Inlet 7-
Air Exhaust 8-
Power Cord Holder 9-
Water Stopper (rubber plug inside) |
|
Accessories 10- Inner adaptor, for inserting the tube in the back of the unit
11-
Evacuation pipe 12-
Double connector, adaptor and conduit 13-
Water tank 14-
Remote control |
|
INSTALLATION
Setting up the cap to guide air flow
You can install
the cap provided should you wish to direct the airflow.

Setting up the Air
Conditioner.
This unit is a
PORTABLE AIR CONDITIONER that can be moved from room to room allowing fresh air
to follow you wherever you go. It is easy to mount using either a door or a
window. Please refer to the instructions
that follow:
1.
Using a window
Slightly open the
window to let the evacuation pipe expel warm air outside.

Depending on the
type of window you have, you can make the unit more efficient by filling the
open space in the window with the kit provided. This way, the cooled air stays
entirely in the room.

2.
Using a door

Slightly open the door in order to let the pipe expel any warm air
outside the room.
INSTALLATION
Installing the evacuation pipe
|
1-
The evacuation pipe provided extends from 300mm to
1500 mm For maximum efficiency, keep the pipe as
short as possible. 2-
Use only the evacuation pipe provided. Attach both
it and the adaptor to the back of the air conditioner. 3-
Avoid kinks and bends in the exhaust pipe as this
will cause expelled moist air to build up causing the unit to overheat and
shut down. (Fig 8 and 9) WARNING! The evacuation pipe provided is designed specially for this appliance.
Do not replace it or extend it
yourself, as this could cause the unit to malfunction. (Fig10) |
|
|
Control panel |
|
||
|
|
|||
|
ON/OFF Press the ON/OFF switch and the unit will start
automatically. If room temperature is: - above 23oC,
the unit will work in cooling mode. - above 20 oC but below or
equal to 23 oC, the unit
will work in ventilation mode. Mode indicators will come on at the same time.
*NOTE! The COMPRESSOR indicator will only light up when the compressor is in
operation. The numeric display shows the room temperature. To turn the unit off, press the ON/OFF switch again. Setting the
mode Press MODE button to select the working mode
desired: automatic, cooling, fan. The relevant indicator will light up. Setting the
temperature Press the 'Temp.up' or
'Temp. down' buttons to regulate the temperature. While you press these buttons, the numeric display
will indicate the current temperature chosen. At any other time it will
indicate current room temperature. The non-adjustable preset temperature on automatic
mode is 23 oC. |
|||
Heating mode
In heating mode you can
settle the temperature between 15°C to 31°C. When the sensor detects that the
room temperature is lower than the one chosen the heater starts running. When
the sensor detects that the room temperature is higher than the one chosen the
heater stops running. When the sensor detects that the room temperature is
higher than 20°C, the unit works in high fan speed.
Setting the ventilation speed
1. Press the
SPEED button to choose the ventilation speed you need, high, medium or low.
2. If the unit
is in AUTO mode, it will automatically select the ventilation speed according
to the room temperature (the related indicators will light on). You will not be
able to control the speed manually in automatic mode.
Setting the timer
1. Press
TIMER button to set the length of operation (from 30 minutes to 12 hours). The time indicator will
light up). Once the chosen length of time has passed, the machine will turn off
automatically. The digital display will show the time chosen. If the timer
button is not pressed, the unit will work continuously.
2.
To preset a starting time, press only the timer and no
other function buttons. For example, if you set the timer to '2', the unit will
start automatically two hours later.
|
All these
functions can be regulated with the remote control provided. This
remote control requires two AAA batteries. |
|
Regulating the air flow
|
|
|
|
Turn the knob to control direction of airflow through
the vertical louvers. |
Move the
air vents by hand to adjust the direction of airflow through the horizontal
louvers. |
TAKE
NOTE!
1-
To prolong the compressor
life, please wait for at least three minutes after turning off the unit before
turning it on again.
2-
The cooling system will
switch off if the temperature is lower than the one set. The ventilation,
however, will continue to function. If the temperature rises above the one
chosen, the cooling function will start again.
DRAINAGE
During the cooling process, the appliance will
extract an amount of water from the air. If the water reservoir inside the unit
is full, both the compressor and motor will stop. The COMP. indicator will flash
.
Before the air conditioner will work again, you
will need to remove the water from the unit. There are two ways to drain this
water:
-
Use the provided water tray
-
Use permanent drainage
|
Use
water tray (provided ) 1- Turn off the unit. Do not move it. 2- Position the plastic water tray provided flat on the floor under the
water hole. 3- Remove the drain knob & rubber plug, the
water will drain out automatically. 4- When the water tray is almost full, replace the rubber plug to stop
the water and empty the water tray. 5- Repeat steps 2, 3, and 4 until all water has been drained. 6- After all water has gone, firmly put the rubber plug back into the
drain hole. The “full water” indicator should be off now. 7- Replace the drain knob. Continuous
Drainage 1- Remove the drain knob and rubber plug, keep them for future use.
(fig22) 2- Connect drainpipe (fig 23) to the water hole at the back of the unit. 3- Bring the other end of drainpipe to a drain: The drain must be at or
below the level of the unit. The water will drip directly into the drain. 4-
If you want to extend the
water tube, you can connect it with another one (OD: 18mm). 5-
The “Comp” indicator will not blink if you drain the unit
in this way. |
|
MAINTENANCE
Always
switch off then unplug the unit from the mains before cleaning.
Cleaning
the outside
Use a soft, damp cloth and wipe the outside.
Never use aggressive chemicals, gasoline,
detergents, chemically treated cloths, or other cleaning solutions. These could
damage the unit.
Cleaning
the filters
Use a vacuum cleaner or tap the filter lightly
to remove loose dust and dirt and then rinse thoroughly under running water (no
hotter than 40°C). Allow to dry completely before replacing.
PLEASE
NOTE! Never use the unit without the filters.
End Of Season Storage
Switch off then unplug the unit.
Drain any water COMPLETELY.
Clean or change the active carbon filter.
On a sunny day, turn unit to ventilation mode
for a couple of hours to dry out the inside.
Do not store appliance in its original
packaging.
Do not stack heavy objects on the unit.
Power Supply Cord
|
|
When the
Air Conditioner is not in use, please wind supply cord on its holder at the
back of the unit. |
TROUBLESHOOTING SECTION
|
The air
conditioner isn’t working |
Is it plugged in? It is switched on? Is the “FULL WATER” (“COMP”) indicator on? (if so, empty the
appliance). Is the room temperature within the appliance’s
range of operation? |
The air conditioner isn’t
really making a difference
|
Is the room too sunny? (Please draw the
curtains.) Are too many windows or doors open? Are there too many people in the room? Is there something in the room producing a lot
of heat? |
|
The air
conditioner makes no difference at all |
Is the filter dirty? Are the air input or output blocked? Is the room temperature below the temperature
you set? |
|
Too
noisy |
Is the unit on an uneven surface? This can
cause vibrations. It must be on a sturdy, flat surface. |
|
The
compressor isn’t working |
The compressor’s overheating protector might
be on. Wait for the temperature to drop. |
L NEVER TRY TO REPAIR OR DISMANTLE THE AIR CONDITIONER
YOURSELF.
Warranty: One year for
initial owner.
To prove rights to warranty,
please include proof of purchase when you return the machine or send it to your
seller.