SPECIFICATIONS

MODEL

SC12ETC

Power supply

230V  50Hz

Coolant

R-407C

Coolant capacity

520 g

Ventilation speeds

3

Net weight

32kgs

Dimensions

377 x 446 x 738 mm (W x D x H)

 


BEFORE USE

Caution!

Plug the unit directly into an earthed electrical outlet and operate only at the recommended voltage. (Please refer to the sticker on the back of the unit.)

Do not use this unit for any other purpose than those described in this owner’s manual.

Always ensure that the unit stands vertically on a flat, stable surface (FIG.1)

Do not obstruct the air inlet and outlet grilles. (FIG.2)

Do not use the product in a humid room, such as a bathroom or laundry room. (FIG.3)

Position the unit at least 50cm from walls and other obstructions (furniture, curtains….) (FIG.4)

Do not put anything on top of the unit.

Do not handle the unit with wet hands when barefoot.

Do not let chemical substances come into contact with the unit.

Do not use the unit near flammable substances such as alcohol, insecticides, petrol etc.

Do not turn off the unit at the socket. Always use the ”ON/OFF” switch on the control panel.

If unit is malfunctioning, always switch it off and unplug it.

Always switch off and unplug unit before cleaning it.

Watch children and pets while the unit is in operation. They are unaware of the dangers posed by electrical applicances.

 

 

 


BEFORE USE

-          If the electrical socket is different from the plug, have a qualified electrician replace it with a suitable one. Avoid the use of adaptors, multiple adaptors and / or extension cables. If you absolutely must use them, ensure they conform to current safety regulations.

 

-          Do not pull the power cord or place it near a heat source; always unwind it completely to avoid dangerous overheating.

 

-  Should the power supply cable become damaged, avoid any risk of danger by getting it replaced by a qualified person.

 

-     Never use the unit without the filter.

 

-          Switch off and then unplug the unit when it is not in use.

 

-     This appliance should only be used indoors.

 

THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.

 

For  maximum efficiency.

-          Do not locate air near furniture or other objects that could obstruct airflow.

-          Keep blinds/curtains closed during the sunniest part of the day.

-          Close or block chimneys and other passages so cool air does not escape.

-          Keep the filters clean.

-          When you first turn on the unit, set it to maximum speed and then adjust to the temperature desired.


PARTS

 

Front                                                                  Back

                          

 

 

 

 

 

1-       Control Panel

2-       Cool Air Outlet

3-       Handle

4-     Casters

 

 

 

5-       Air Filter

6-       Air Inlet

7-       Air Exhaust

8-       Power Cord Holder

9-     Water Stopper (rubber plug inside)

 

Accessories

 

10-  Inner adaptor, for inserting the tube in the back of the unit

11-   Evacuation pipe

12-   Double connector, adaptor and conduit

13-   Water tank

14-   Remote control

 

 

 

 


 

INSTALLATION

Setting up the cap to guide air flow

You can install the cap provided should you wish to direct the airflow.

 


Setting up the Air Conditioner.

This unit is a PORTABLE AIR CONDITIONER that can be moved from room to room allowing fresh air to follow you wherever you go. It is easy to mount using either a door or a window.  Please refer to the instructions that follow:

 

 

1.       Using a window

 

Slightly open the window to let the evacuation pipe expel warm air outside.

 

 

Depending on the type of window you have, you can make the unit more efficient by filling the open space in the window with the kit provided. This way, the cooled air stays entirely in the room.

 

2.       Using a door

Slightly open the door in order to let the pipe expel any warm air outside the room.

 

INSTALLATION

 

Installing the evacuation pipe

 

 

 

1-       The evacuation pipe provided extends from 300mm to 1500 mm For maximum efficiency, keep the pipe as short as possible.

2-       Use only the evacuation pipe provided. Attach both it and the adaptor to the back of the air conditioner.

3-       Avoid kinks and bends in the exhaust pipe as this will cause expelled moist air to build up causing the unit to overheat and shut down. (Fig 8 and 9)

 

WARNING!

 

The evacuation pipe provided is designed specially for this appliance. Do not replace it or extend it yourself, as this could cause the unit to malfunction. (Fig10)

 

 

OPERATING INSTRUCTIONS.

 

Control panel

 

 

 

 

1. “On/Off” switch.

When using the unit for the first time, press this to activate it; the unit will start in automatic mode. To stop, press switch again.

When you subsequently activate the unit with this switch, the unit will run according to the setting used, but the timer will reset to 0.

 

2. “Timer”: Timer control button. Press this button to get time desired; the screen will display times from 0.5 to 12 hours. To go back to 0 keep pressing after 12.

 

3. “Mode”: Switch that allows you to choose between the following modes: automatic, cooling, fan, humidifier, heater. An icon representing the chosen mode on the screen.

 

4.”Speed”: This button controls the unit’s speed. Three speeds are available and the one chosen will appear on the screen.”

5. “Temp. up” & “Temp. down”: These buttons control the temperature, which must lie between 15°C and 31°C. The default temperature for automatic mode is 23°C.

 

6.   Temperature indicator

 

7.   Automatic mode indicator

 

8.   Cooling mode indicator

 

9.   On indicator

 

10.   Speed indicator

 

11.   Dehumidifier mode indicator

 

12.   Time indicator

 

13.   Problem indicator

 

14.   Heater mode indicator

 

ON/OFF

Press the ON/OFF switch and the unit will start automatically. If room temperature is:

   - above 23oC, the unit will work in cooling mode.

   - above 20 oC but below or equal to  23 oC, the unit will work 

     in ventilation mode.

 

Mode indicators will come on at the same time. *NOTE! The COMPRESSOR indicator will only light up when the compressor is in operation.

The numeric display shows the room temperature.

To turn the unit off, press the ON/OFF switch again.

 

Setting the mode

Press MODE button to select the working mode desired: automatic, cooling, fan. The relevant indicator will light up.

 

Setting the temperature

Press the 'Temp.up' or 'Temp. down' buttons to regulate the temperature.

While you press these buttons, the numeric display will indicate the current temperature chosen. At any other time it will indicate current room temperature.

The non-adjustable preset temperature on automatic mode is 23 oC.

 

Heating mode

 

In heating mode you can settle the temperature between 15°C to 31°C. When the sensor detects that the room temperature is lower than the one chosen the heater starts running. When the sensor detects that the room temperature is higher than the one chosen the heater stops running. When the sensor detects that the room temperature is higher than 20°C, the unit works in high fan speed.

 

 

Setting the ventilation speed

1. Press the SPEED button to choose the ventilation speed you need, high, medium or low.

2. If the unit is in AUTO mode, it will automatically select the ventilation speed according to the room temperature (the related indicators will light on). You will not be able to control the speed manually in automatic mode. 

 

 

Setting the timer

1.       Press TIMER button to set the length of operation (from 30 minutes to 12 hours). The time  indicator will light up). Once the chosen length of time has passed, the machine will turn off automatically. The digital display will show the time chosen. If the timer button is not pressed, the unit will work continuously.

2.       To preset a starting time, press only the timer and no other function buttons. For example, if you set the timer to '2', the unit will start automatically two hours later.

All these functions can be regulated with the remote control provided.

This remote control requires two AAA batteries.

FIG. 19

 

Regulating the air flow

  FIG.20

  FIG.21

Turn the knob to control direction of airflow through the vertical louvers.

Move the air vents by hand to adjust the direction of airflow through the horizontal louvers.

 

TAKE NOTE!

 

1-      To prolong the compressor life, please wait for at least three minutes after turning off the unit before turning it on again.

2-      The cooling system will switch off if the temperature is lower than the one set. The ventilation, however, will continue to function. If the temperature rises above the one chosen, the cooling function will start again.

 

 

 


DRAINAGE

 

During the cooling process, the appliance will extract an amount of water from the air. If the water reservoir inside the unit is full, both the compressor and motor will stop.  The COMP. indicator will flash .

 

Before the air conditioner will work again, you will need to remove the water from the unit. There are two ways to drain this water:

 

-          Use the provided water tray

-          Use permanent drainage

 

 

 

Use water tray (provided )

 

1-      Turn off the unit. Do not move it.

2-      Position the plastic water tray provided flat on the floor under the water hole.

3-      Remove the drain knob & rubber plug, the water will drain out automatically.

4-      When the water tray is almost full, replace the rubber plug to stop the water and empty the water tray.

5-      Repeat steps 2, 3, and 4 until all water has been drained.

6-      After all water has gone, firmly put the rubber plug back into the drain hole. The “full water” indicator should be off now.

7-      Replace the drain knob.

Continuous Drainage

1-      Remove the drain knob and rubber plug, keep them for future use. (fig22)

2-      Connect drainpipe (fig 23) to the water hole at the back of the unit.

3-      Bring the other end of drainpipe to a drain: The drain must be at or below the level of the unit. The water will drip directly into the drain.

4-     If you want to extend the water tube, you can connect it with another one (OD: 18mm).

5-     The “Comp” indicator will not blink if you drain the unit in this way.

 

 


MAINTENANCE

Always switch off then unplug the unit from the mains before cleaning.

 

Cleaning the outside

Use a soft, damp cloth and wipe the outside.

Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleaning solutions. These could damage the unit.

 

Cleaning the filters

Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt and then rinse thoroughly under running water (no hotter than 40°C). Allow to dry completely before replacing.

 

PLEASE NOTE! Never use the unit without the filters.

 

End Of Season Storage

Switch off then unplug the unit.

Drain any water COMPLETELY.

Clean or change the active carbon filter.

On a sunny day, turn unit to ventilation mode for a couple of hours to dry out the inside.

Do not store appliance in its original packaging.

Do not stack heavy objects on the unit.

 

Power Supply Cord

 

 

 

When the Air Conditioner is not in use, please wind supply cord on its holder at the back of the unit.

 


TROUBLESHOOTING SECTION

The air conditioner isn’t working

Is it plugged in?

It is switched on?

Is the “FULL WATER” (“COMP”) indicator on?

(if so, empty the appliance).

Is the room temperature within the appliance’s range of operation?

The air conditioner isn’t really making a difference

Is the room too sunny? (Please draw the curtains.)

Are too many windows or doors open?

Are there too many people in the room?

Is there something in the room producing a lot of heat?

The air conditioner makes no difference at all

Is the filter dirty?

Are the air input or output blocked?

Is the room temperature below the temperature you set?

Too noisy

Is the unit on an uneven surface? This can cause vibrations. It must be on a sturdy, flat surface.

 

 

The compressor isn’t working

The compressor’s overheating protector might be on. Wait for the temperature to drop.

L NEVER TRY TO REPAIR OR DISMANTLE THE AIR CONDITIONER YOURSELF.

 

Warranty: One year for initial owner.

 

To prove rights to warranty, please include proof of purchase when you return the machine or send it to your seller.