SPECIFICATIONS
|
MODEL |
SC09ET |
|
Power supply |
220-240V 50Hz |
|
Coolant |
R-407C |
|
Coolant capacity |
480 g |
|
Ventilation speeds |
3 |
|
Net weight |
32kgs |
|
Dimensions |
377 x 446 x 738 mm (W x D x H) |
BEFORE USE
|
Plug the unit directly into an earthed electrical outlet and operate
only at the recommended voltage. (Please refer to the sticker on the back of
the unit.) Do not use this unit for any other purpose than those described in
this owner’s manual. Always ensure that the unit stands vertically on a flat, stable
surface (FIG.1) Do not obstruct the air inlet and outlet grilles. (FIG.2) Do not use the product in a humid room, such as a bathroom or laundry
room. (FIG.3) Position the unit at least 50cm from walls and other obstructions
(furniture, curtains….) (FIG.4) Do not put anything on top of the unit. Do not handle the unit with wet hands when barefoot. Do not let chemical substances come into contact with the unit. Do not use the unit near flammable substances such as alcohol,
insecticides, petrol etc. Do not turn off the unit at the socket. Always use the
”ON/OFF” switch on the control panel. If unit is malfunctioning, always switch it off and unplug it. Always switch off and unplug unit before cleaning it. Watch children and pets while the unit is in operation. They are
unaware of the dangers posed by electrical applicances. |
|
-
If
the electrical socket is different from the plug, have a qualified electrician
replace it with a suitable one. Avoid the use of adaptors, multiple adaptors
and / or extension cables. If you absolutely must use them, ensure they conform
to current safety regulations.
-
Do
not pull the power cord or place it near a heat source; always unwind it
completely to avoid dangerous overheating.
- Should the power supply cable become damaged,
avoid any risk of danger by getting it replaced by a qualified person.
- Never use the unit without the filter.
-
Switch
off and then unplug the unit when it is not in use.
- This appliance should only be used indoors.
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF
THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.
For maximum efficiency.
-
Please
use the unit in the recommended room size:
18 m˛, 50 m3 (See
SPECIFICATIONS.)
-
Do
not locate air near furniture or other objects that could obstruct airflow.
-
Keep
blinds/curtains closed during the sunniest part of the day.
-
Close
or block chimneys and other passages so cool air does not escape.
-
Keep
the filters clean.
-
When
you first turn on the unit, set it to maximum speed and then adjust to the
temperature desired.
PARTS
Front
Back

|
1-
Control Panel 2-
Cool Air Outlet 3-
Handle 4- Casters |
5-
Air Filter 6-
Air Inlet 7-
Air Exhaust 8-
Power Cord Holder 9- Water Stopper (rubber plug inside) |
|
Accessories 10- Inner adaptor, for inserting the tube in the back of the unit
11-
Evacuation pipe 12-
Double connector, adaptor and conduit 13-
Water tank 14-
Remote control |
|
INSTALLATION
Setting up the cap to guide air flow
You can
install the cap provided should you wish to direct the airflow.

Setting up the Air
Conditioner.
This unit is a PORTABLE AIR
CONDITIONER that can be moved from room to room allowing fresh air to follow
you wherever you go. It is easy to mount using either a door or a window. Please refer to the instructions that follow:
1.
Using a window
Slightly
open the window to let the evacuation pipe expel warm air outside.

Depending
on the type of window you have, you can make the unit more efficient by filling
the open space in the window with the kit provided. This way, the cooled air
stays entirely in the room.

2.
Using a door

Slightly open the door in order to let the pipe
expel any warm air outside the room.
INSTALLATION
Installing
the evacuation pipe
|
1-
The evacuation pipe provided extends from 300mm to 1500 mm For maximum efficiency, keep the pipe as short as
possible. 2-
Use only the evacuation pipe provided. Attach both it and the adaptor
to the back of the air conditioner. 3-
Avoid kinks and bends in the exhaust pipe as this will cause expelled
moist air to build up causing the unit to overheat and shut down. (Fig 8 and
9) WARNING! The
evacuation pipe provided is designed specially for this appliance. Do not replace it or extend it
yourself, as this could cause the unit to malfunction. (Fig10) |
|
|
Control
panel |
|
||
|
6 7 8 9 10 11 12 13
5 4 3 2 1
|
|||
|
ON/OFF Press the ON/OFF switch and the
unit will start automatically. If room temperature is: - above 23oC, the unit will work in cooling mode. - above 20 oC but below or equal
to 23 oC, the unit will work
in ventilation
mode. Mode indicators will come on at
the same time. *NOTE! The COMPRESSOR indicator will only light up when the
compressor is in operation. The numeric display shows the room
temperature. To turn the unit off, press the
ON/OFF switch again. Setting
the mode Press MODE button to select the
working mode desired: automatic, cooling, fan. The relevant indicator will
light up. Setting
the temperature Press the 'Temp.up'
or 'Temp. down' buttons to regulate the temperature. While you press these buttons,
the numeric display will indicate the current temperature chosen. At any
other time it will indicate current room temperature. The non-adjustable preset
temperature on automatic mode is 23 oC. |
|||
Setting the ventilation speed
1. Press
the SPEED button to choose the ventilation speed you need, high, medium or low.
2. If the unit is in
AUTO mode, it will automatically select the ventilation speed according to the
room temperature (the related indicators will light on). You will not be able
to control the speed manually in automatic mode.
Setting the timer
1.
Press TIMER button to set the length of operation (from
30 minutes to 12 hours). The time indicator will light up). Once the
chosen length of time has passed, the machine will turn off automatically. The digital
display will show the time chosen. If the timer button is not pressed, the unit
will work continuously.
2.
To
preset a starting time, press only the timer and no other function buttons. For
example, if you set the timer to '2', the unit will start automatically two
hours later.
|
All these
functions can be regulated with the remote control provided. This remote control requires two AAA
batteries. |
|
Regulating the air
flow
|
|
|
|
Turn the knob to control direction
of airflow through the vertical louvers. |
Move the air vents
by hand to adjust the direction of airflow through the horizontal louvers. |
TAKE NOTE!
1-
To prolong the compressor
life, please wait for at least three minutes after turning off the unit before
turning it on again.
2-
The cooling system will
switch off if the temperature is lower than the one set. The ventilation,
however, will continue to function. If the temperature rises above the one
chosen, the cooling function will start again.
DRAINAGE
During the cooling process, the appliance will
extract an amount of water from the air. If the water reservoir inside the unit
is full, both the compressor and motor will stop. The COMP. indicator will flash
.
Before the air conditioner will work again, you
will need to remove the water from the unit. There are two ways to drain this
water:
-
Use the provided water tray
-
Use permanent drainage
|
Use
water tray (provided ) 1- Turn off the unit. Do not move it. 2- Position the plastic water tray provided flat on the floor under the
water hole. 3- Remove the drain knob & rubber plug, the
water will drain out automatically. 4- When the water tray is almost full, replace the rubber plug to stop
the water and empty the water tray. 5- Repeat steps 2, 3, and 4 until all water has been drained. 6- After all water has gone, firmly put the rubber plug back into the
drain hole. The “full water” indicator should be off now. 7- Replace the drain knob. Continuous
Drainage 1- Remove the drain knob and rubber plug, keep them for future use.
(fig22) 2- Connect drainpipe (fig 23) to the water hole at the back of the unit. 3- Bring the other end of drainpipe to a drain: The drain must be at or
below the level of the unit. The water will drip directly into the drain. 4-
If you want to extend the
water tube, you can connect it with another one (OD: 18mm). 5-
The “Comp” indicator will not blink if you drain the unit
in this way. |
|
MAINTENANCE
Always switch off then unplug the unit from the mains
before cleaning.
Cleaning the outside
Use
a soft, damp cloth and wipe the outside.
Never
use aggressive chemicals, gasoline, detergents, chemically treated cloths, or
other cleaning solutions. These could damage the unit.
Cleaning the filters
Use
a vacuum cleaner or tap the filter lightly to remove loose dust and dirt and
then rinse thoroughly under running water (no hotter than 40°C). Allow to dry
completely before replacing.
PLEASE NOTE! Never use the unit without the filters.
End Of Season Storage
Switch
off then unplug the unit.
Drain
any water COMPLETELY.
Clean
or change the active carbon filter.
On a
sunny day, turn unit to ventilation mode for a couple of hours to dry out the
inside.
Do
not store appliance in its original packaging.
Do
not stack heavy objects on the unit.
Power Supply Cord
|
|
When the Air Conditioner is not in use,
please wind supply cord on its holder at the back of the unit. |
TROUBLESHOOTING
SECTION
|
The
air conditioner isn’t working |
Is it plugged in? It is switched on? Is the “FULL WATER” (“COMP”) indicator on? (if so, empty the
appliance). Is the room temperature within the
appliance’s range of operation? |
The air conditioner
isn’t really making a difference
|
Is the room too sunny? (Please draw the
curtains.) Are too many windows or doors open? Are there too many people in the room? Is there something in the room producing a
lot of heat? |
|
The
air conditioner makes no difference at all |
Is the filter dirty? Are the air input or output blocked? Is the room temperature below the temperature
you set? |
|
Too
noisy |
Is the unit on an uneven surface? This can
cause vibrations. It must be on a sturdy, flat surface. |
|
The
compressor isn’t working |
The compressor’s overheating protector might
be on. Wait for the temperature to drop. |
L NEVER TRY TO REPAIR OR DISMANTLE THE AIR CONDITIONER YOURSELF.
Warranty: One year for
initial owner.
To prove rights to
warranty, please include proof of purchase when you return the machine or send
it to your seller.