PURLINE
DEHUMIDIFIER
PLZ10MA
OWNER’S MANUAL

WinEurope SA – France
N° Indigo : +
33 0 825 875 532
Email : info@purline.com
Internet : www.purline.com
BEFORE USING THIS DEHUMIDIFIER PLEASE READ THESE
INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE.
Thank you for choosing this PURLINE dehumidifier.
To enjoy the many benefits that this appliance has to offer please read this
manual carefully and keep it for future reference.
IMPORTANT SAFEGUARDS
-
Keep power supply cord out of the
way, where it cannot be
stepped on or tripped over.
-
Do not use flammable agents to clean
the unit, they
could damage the plastic and start a fire.
-
Place unit on a flat, stable
surface.
-
Never place laundry to dry on the
dehumidifier, the clothes rack should be set at least 50cm away from the unit.
-
Do not insert any objects into the
air outlet, it would damage the unit.
-
When the dehumidifier is operating one
window can be half-open but DO NOT open any more windows
or doors.
-
Do not place the unit near heating
devices or in direct sunlight.
-
Always keep the unit upright while
moving it or when it is stored.
-
Leave the dehumidifier to stand for
two hours before connecting to the mains supply after transport or if it has
been tilted.
-
HOW IT WORKS
DO YOU KNOW THAT DRY AIR IS WARMING UP FASTER
THAN DAMP AIR ?
DEHUMIDIFIERS ARE DESIGNED FOR USE IN DAMP
LOCATIONS AND ROOMS WITH HUMIDITY PROBLEMS: THIS IS WHERE THEY SHOULD BE
LOCATED.
As soon as your dehumidifier is “ON” it starts
protecting you and your residence from the ill effects of humidity.

The dehumidifier controls humidity by forcing
excess moisture to condense from the air into the unit as it passes over the
cooling elements. This condensed water then drains safely into the water tank.
The dried air then passes through a coil where
it is slightly warmed and re-enters the room at a slightly elevated
temperature: YOU SAVE ENERGY!


OPERATING INSTRUCTIONS
Plug the power cord into a 230 V ~ 50Hz grounded wall
outlet, then turn the humidistat knob clockwise to start the dehumidifier.
Your dehumidifier will start functioning.
CAUTION :
This dehumidifier cannot be used at a room temperature below 5°C.
AUTOMATIC DEFROST
Your dehumidifier is fitted with an automatic
defrost system. When ambient temperature decreases to 15°C or less, the humidity
sensitive coils will be covered with frost. Automatic Defrost will start when needed : the warning light
will light up while defrosting take place. Once
the defrosting process is over, the “Defrost” warning light will go off.
EMPTYING THE WATER TANK

Disconnect the unit from the wall socket before
removing the water tank.
When the water tank is full (or has not been
positioned correctly), the unit will shut off automatically and the warning light
will light up : the
water tank needs to be emptied. Pull out the water tank from the unit, after
emptying the water tank carefully replace it into the dehumidifier. When the
water tank is properly positioned the “FULL” light will go out. The dehumidifier is operational.
The water tank must be properly positioned and
fully inserted in its cavity (to activate the overflow protection switch.
CONTINUOUS DRAINAGE
PLEASE NOTE : BOTH THE
WATER TANK AND THE CONTINUOUS DRAINAGE CANNOT BE USED AT THE SAME TIME.
Switch off and disconnect the unit from the wall
socket before proceeding.
You must empty the water tank on a regular
basis.
The water can be drained continuously by
attaching a direct drain hose to the unit.
(hose available at your
local Hardware Store).
This is useful if your dehumidifier is located
in a high humidity environment or in premises which are infrequently used.
Installing a direct drain :
1. Use
a tool to remove the plastic tab at the rear of the dehumidifier.
2. Remove
the water tank.
3. Insert
a water tube inside the hole (rear) of the
dehumidifier.
4. Attach
the hose to the unit drain connection (over the reservoir)
5. Replace
the reservoir.
PLEASE NOTE : the dehumidifier will not function if the reservoir
is not relocated in its cavity.
The other
hose extremity can be directed to a floor drain. The hose must be made of rigid
material it should not bend. The hose must be below the continuous drain
connector.
Be careful
not to let the hose extremity get into the drain water.
|
|
|
PLEASE NOTE : when operating the dehumidifier in cool
conditions, you must ensure that the hose cannot freeze.
MAINTENANCE
Switch off and disconnect the unit before
cleaning.
CLEANING
THE UNIT
Always switch off and disconnect the
dehumidifier from the wall socket before cleaning. Wipe the unit shell with a soft clean cloth and
mild soap. Do not use detergents or abrasives which could damage the plastic.
CLEANING
THE FILTER
Switch off and disconnect the dehumidifier.
The filter is located behind the water tank (see
figure 1)
1. Remove
the water tank.
2. Remove
the filter
3. Vacuum
the filter taking care of not damaging it.
4. Replace
filter
5. Replace
reservoir
STORAGE
Pack your unit and the owner’s manual in its
original box and store in a cool, well ventilated place.
CAUTION
TROUBLE-SHOOTING
|
TOUBLE |
PROBABLE CAUSE |
SOLUTION |
|
Compressor and fan do not run. |
No power or incorrect voltage. |
Check with an electrician |
|
Faulty plug. Short circuit. |
Check with an electrician |
|
|
Fan runs but not compressor. |
Defrosting in-progress |
Wait for end of cycle |
|
Allow 3 minutes for delayed start. |
|
|
|
Ambient temperature too low. |
Normal, compressor protection
. |
|
|
Very noisy unit. |
Uneven floor. |
Install unit on a hard level surface |
|
Compressor or motor are loose. |
Check with service department. Parts must be tighten. |
|
|
« you can hear running liquid» |
Normal :
refrigerant is flowing through the coils. |
|
|
No or insufficient dehumidification. |
Dirty filter. |
Clean filter |
|
Refrigerant leaking |
Check with service department. |
|
|
Ambient temperature too low - No Humidity to
remove |
Normal |
|
|
Evaporator covered with frost. |
Filter too dirty. |
Clean filter. |
|
Ambient temperature too low. |
Normal |
|
|
Overflowing or leaking water tank. |
Water tank leak |
Replace tank |
|
Faulty full tank auto switch. |
Check with service department. |
PLEASE NOTE :
Excessive dampness will quickly be reduced from
the air. However if the location where the unit is operating is extremely damp,
you will need a few days or even weeks
before you start obtain a comfortable humidity rate.
Condensation on a cold surface is NORMAL. The
dehumidifier reduces the air humidity rate and you should notice less
condensation on cold windows.
IMPORTANT
It is necessary to
wait 2 to 3 minutes before restarting the unit when it has been shut off. This
allows the refrigeration system to stabilize.
TECHNICAL SPECIFICATIONS
Model: PLZ10MA
Recommended room temperature : 5°C
to 35°C
Dehumidification
capacity 5
L/DAY at 27°C/ RH 60%
10
L/DAY at 30°C/ RH 80%
Reservoir capacity : about
4 Litres
Weight : 12
Kg
Dimensions (W x D x H) :
312 x 283 x 561 mm
Power Consumption :
240 W
Input Voltage : 220
V-240V ~ 50 Hz
Current: 1,4 A
WARRANTY: 1 YEAR TO FIRST BUYER.
TO RECLAIM YOUR WARRANTY,