EN
USER GUIDE
MODEL HGC2
ATTENTION: It is important to
clean your humidifier every week. Please check cleaning procedures (Pages 5 and
6)

|
TABLE OF
CONTENTS 1.
Directions for use
|
6.
Suggestions |
THANK YOU
FOR CHOOSING A PURLINE HUMIDIFIER.
Please read
and keep this user guide before you start using your humidifier.
Your
humidifier must be maintained properly to work satisfactorily.
|
WinEurope SA Paris – France N° INDIGO :
0.825.875.532 Email : info@purline.com Internet : www.purline.com |
How to use your humidifier.
Be careful
to :
- Not
introduce any foreign material into the vapour chamber or inlet.
- When
connected the humidifier must not be emptied, be moved; if knocked down there
is danger of electrocution.
- Before connecting the humidifier, you must verify the supply cord
and wall socket.
- When the humidifier is in function, keep your
face away from the vapour, do not touch it, there is danger of burning.
- A non suitable socket could provoke a fire.
- Do not
immerse the humidifier.
- Clean the
humidifier once a week with a soft cloth.
- Do not
fill the reservoir when the unit is in function, there is danger of burning.
- Do not
use another appliance during the cleaning.
- Do not
block the air inlet and outlet when the unit is connected.
- Do not
place the humidifier in a place where it could overturn.
- Do not to
clean with a solvent, this could alter the colour and finish.
- Do not
move the device to clean it when it works, the warm water could spill and cause
burning.
DURING
INSTALLATION
- Locate
the humidifier OUT OF REACH of children.
- Do not
use the humidifier near an electric heater, fireplace etc. the plastic
materials of the humidifier are flammable.
- Do not
install the humidifier on a carpet, the lack of aeration could become
dangerous.
- Do not
install the humidifier near furniture or directly under a ceiling, humidity
could damage the finish.
- Do not
place the humidifier on a slant or unstable support, this could prevent its
function and spill the water.
SPECIFICATIONS
Model HGC2
Type Heating
element
Water Tap water
Capacity 300 cc / hour
Thermostat 130°C
Circuit
breaker 141 °C
Continuous
function about 8 hours
Area
coverage 40 m ² / 96
m3
Reservoir
capacity 2,3 litres
Electric
consumption 260 watts + /-15 %
Supply cord 2
m
Dimensions 215 mm x 255mm x 185 mm
Weight 1.5 kg
Made in P.R.C.
WATER
REFILL
To fill the
reservoir.
1. Remove the reservoir cap and fill
it with tap water about 1/3 of the reservoir.
2. Refit the cap and shake strongly;
empty the reservoir.
3. Refill with water again.
Attention.
- Do not place the water faucet in
the steam exhaust.
- Do not use water warmer over
40°C.
- Relocate reservoir in its
location.
Connect to
a wall socket - 230V / 50HZ
ATTENTION
- To disconnect the humidifier,
pull on the wall socket itself, not on the cord.
- Do not use the humidifier if the
supply cord or the plugs are damaged, it could cause a short circuit..
- Handle the electric cordon with
care.
- Disconnect the device when not in
use.
- If the supply cord is damaged,
please have it replaced by the manufacturer, a Service Station or similarly
qualified person in order to avoid a hazard.
Store away.
- Clean the unit and remove all
calcium..
- Follow the (6) cleaning steps,
dry up the unit.
- Store away in the original
packing
CLEANING
AND MAINTENANCE
Disconnect
the humidifier before cleaning.
Do not use
the humidifier if it is full of calcium, or damaged, if there is no water evaporation, if there
are moulds or bad smells. It could be harmful.
Close the
reservoir cap and replace in its location.
ATTENTION
Do not use
the humidifier next to a connected appliance, such as a television, a
"hi-fi system" etc...
Not to
leave the unit connected if the
reservoir is empty.
The
humidifier is easily maintained, please proceed as follows:

Disconnect the humidifier, remove and empty
the reservoir.
-
With
some water and a soft cloth, wipe the reservoir inside and out. Do not use
abrasives. Rinse well.
-
Handle
humidifier with care, the unit could be
damaged by falling.
-
Clean
the humidifier the same way as the reservoir, inside and out with a soft cloth
and mild soap; this must be done once a
week.
-
Use
a good clean-away agent to remove all traces of deposits and calcium.
-
Empty
water and minerals from the cavity. Fill the tank with a half cup (125 ml) of a
calcium solvent agent (ref DMS216). Replace the tank, cap down, into the unit.
The cavity will fill with solution and dissolve the calcium. Soak for 20
minutes to a maximum of 30 minutes. Do not operate the unit while it is soaking
in the cleaning agent solution. Rinse thoroughly after cleaning.
-
Rinse
well before re-use. Take good care of your humidifier..
PROBLEMS
AND SOLUTIONS IN CASE OF BREAKDOWN.
|
Warning
light off |
Unit not
connected No Power |
Connect
unit Check
fuses |
|
Poor
vapour output |
Scale
accumulation on heating element |
Clean
unit |
|
Water
leakage |
Damaged
reservoir or seal cap |
Check
improperly fitted seal cap |
ATTENTION:
THIS HUMIDIFIER IS RECOMMENDED FOR USE IN HOUSES AND OFFICES.
Warranty: 1
year to the first buyer.
TO BENEFIT
FROM THE GUARANTEE, THE BUYER MUST RETURN THE UNIT FREIGHT PRE-PAID TO THE
RETAILER WITH HIS PROOF OF PURCHASE.