EN

HYGRO AIR

 

HUMIDIFIER

HA  146

 

USE AND CARE MANUAL

 

 

 

 

 

 

 

 

 

Congratulations !

We thank you for choosing Humidifier HYGRO AIR  HA 146. This equipment has been designed to bring you comfort with optimum energy saving.

READ and SAVE these operating instructions as well as basic safety precautions before using your Humidifier.

 

Get to know your unit.

Read this guide carefully and note all recommended safety precautions prior and after using this equipment; keep your humidifier in good working condition.

Make yourself familiar with instructions and safety guides related to the use of your unit prior to operation.

Keep this user guide for future reference.

 

Carton content

Humidifier body

Evaporative pad holder (drum) with pads

Water tank

 

SAFETY PRECAUTIONS

 

Read all instructions before using this new appliance.

P1-  Unpack unit from packing .

P2 -  Completely unravel power cord. Do not  damage it .

P3 -  Remove adhesive tape from top cover.

P4 -  Remove wedge which holds circular foam holder, then remove holder from humidifier taking hold of its axis.

P5 -  Place drum inside humidifier.

P6 -  Pull slightly outward water tank.

P10 – Place water reservoir in its initial setting.

 

Locating your Humidifier:

For best results we recommend you locate your unit in the middle of premises. If room if heated by pulsed air please set unit near source of pulsed air.

Do not place humidifier near furniture, paintings or any other object which humidity could damage.

Connecting to mains

S1 - Before using the humidifier, extend the cord and inspect for any signs of damage, inspect plug and socket .You should use earth socket.

S2 -Connect the unit to mains (230Volt-50 Hz 10Amps).

Humidifier consumption does not exceed  0.5 Amps (110Wh)

 

Filling up humidifier.

R1 - Make sure the humidifier is switched OFF.

R2 - Unplug unit from mains.

R3 – Flip open filling cover.

R4 -  Be very careful while filling up reservoir, do not spill water on unit controls, or on inside sides of unit. STOP filling 2 cm under water level indicated.

R5 - Wipe dry  any spilled water from control panel. Make sure unit is quite dry  before proceeding.

R6 - Connect humidifier to mains.

 

HOW TO USE YOUR HUMIDIFIER

Please become familiar with the various commands of your humidifier.

F1 –  To turn off unit, switch it "OFF". To turn it on switch it to  the "ON" position. There are 2 speeds (speed 1, speed 2) to choose from.

F2 – The humidistat  (% humidity) allows you to regulate the humidity level in the premises.

If your turn backward the humidistat it will stop the unit. On the contrary if you turn it to its maximum , the unit will run continuously.

F3 – The reservoir float , will stop the humidifier when the amount of water is below 2cm.

F4 – The warning lights (WATER), (% HUMIDITY) and (ON)  indicate at all times if the unit is in good working order.

When the red warning light (WATER)is “ON” the reservoir water level is insufficient. See filling up procedure.

When the orange warning light is ON (% HUMIDITY) the room humidity level is either the same or higher than the Humidistat setting. If a higher level of humidity is required, turn the humidistat clock wise to the required level. The green warning light comes “ON” when the fan is operating, this also means the water level in the reservoir is yet sufficient and the humidistat setting level is yet higher than the room relative humidity level (%humidity).

 

HUMIDIFIER FUNCTION

U1 – The humidistat keeps the humidity level of the room at the required level; the evaporative pads and the fan start and stop automatically when the humidistat

dictates it. The comfort zone is reached depending on the room temperature and the hygrometry level. The higher humidity output is required if the room temperature is raised; this phenomena is even more noticeable if the outside temperature is lower. When the required humidity level is reached, the orange warning light comes on.

(% humidity)

U2 – There are 2 fan speed available. In SPEED 2, the humidity level required will be reached earlier. We recommend you begin in using speed 2 and when the room humidity level is higher, the unit can be set on speed 1 to maintain the best humidity level possible while a lower noise level.

U3 – When the water level is too low, the humidifier stops automatically and the red warning light comes on (WATER).

Use and care

Frequent cleaning is necessary to maximize and extend the life of your humidifier.

Always disconnect the unit from the wall socket before cleaning  and maintenance.

 

N1- Evaporative pads

The humidifier evaporative pads have several functions. They are the most important parts of your humidifier since they perform the following functions :

-          Air cleaning

-          Water filtration

-          Moisture Evaporation

It is essential to keep the pads clean and replace them periodically (yearly) depending on the amount of use, water hardness, local air pollution. To exchange  the pads, remove the humidifier top cover. Grab the wheel axle and remove the red plastic clips holding the outer foam-pad; remove the white clips holding the circular foam-disk.

Clean the foam pads with white vinegar or de-scaling agent or replace with new ones if too old. Relocate in original position. Fix foam pads in correct position with clips and washers.

N2 – Water reservoir

Open the rear door and remove the water reservoir while insuring not to damage the float. Clean all remaining scale with scouring pad. Relocate water reservoir while insuring not to damage the float. Replace back door in position (see P7 and P10, to open and close back door).

N3 – Cleaning inside and outside

Use a soft cloth with mild soap to clean the outside and other inside parts with possible scale deposits of your humidifier.

SPECIFICATIONS

Adjustable humidistat

Power                                                  45 Watts

Evapor. Capacity / 24h                          60 Litres (at 21°C x 30% RH)

Air flow             Speed 1                       450  m3 / H

                        Speed 2                       585  m3 / H

Reservoir capacity                                34 Litres

Power consumption                              45 Watts

Approvals                                             CE

Dimensions (mm)                                 625 x 316 x 720

Net weight                                            18.6 Kg

Shipping dimensions                             670 x 365 x 780

Shipping weight                                    20.6 Kg

Replacement pads ( set of 2 filters)        PUR358           

Automatic refill kit (option)                     WIN1610