EN
HUMIDIFIER
HA 146
USE AND CARE MANUAL

Congratulations
!
We thank you for choosing
Humidifier HYGRO AIR
HA 146. This equipment has been designed to bring you comfort
with optimum energy saving.
READ and SAVE these operating
instructions as well as basic safety precautions before using your Humidifier.
Get
to know your unit.
Read this guide carefully and
note all recommended safety precautions prior and after using this equipment;
keep your humidifier in good working condition.
Make yourself familiar with
instructions and safety guides related to the use of your unit prior to
operation.
Keep this user guide for
future reference.
Humidifier body
Evaporative pad holder (drum) with pads
Water tank
Read
all instructions before using this new appliance.
P1- Unpack unit from packing .
P2 - Completely unravel power cord. Do not damage it .
P3 - Remove adhesive tape from top cover.
P4 - Remove wedge which holds circular foam
holder, then remove holder from humidifier taking hold of its axis.
P5 - Place drum inside humidifier.
P6 - Pull slightly outward water tank.
P10 Place water reservoir
in its initial setting.
Locating
your Humidifier:
For best results we recommend
you locate your unit in the middle of premises. If room if
heated by pulsed air please set unit near source of pulsed air.
Do not place humidifier near
furniture, paintings or any other object which humidity could damage.
S1 - Before using the humidifier,
extend the cord and inspect for any signs of damage, inspect plug and socket
.You should use earth socket.
S2 -Connect the unit to mains
(230Volt-50 Hz 10Amps).
Humidifier consumption does
not exceed 0.5
Amps (110Wh)
Filling up humidifier.
R1 - Make sure the humidifier
is switched OFF.
R2 - Unplug unit from mains.
R3 Flip open filling cover.
R4 - Be very careful
while filling up reservoir, do not spill water on unit controls, or on inside
sides of unit. STOP filling 2 cm under water level indicated.
R5
- Wipe dry any
spilled water from control panel. Make sure unit is quite dry before proceeding.
R6
- Connect humidifier to mains.
Please
become familiar with the various commands of your humidifier.
F1 To turn off unit,
switch it "OFF". To turn it on switch it to the "ON" position. There are
2 speeds (speed 1, speed 2) to choose from.
F2
The humidistat (%
humidity) allows you to regulate the humidity level in the premises.
If
your turn backward the humidistat it will stop the unit. On the contrary if you
turn it to its maximum , the unit will run
continuously.
F3
The reservoir float , will stop the humidifier when
the amount of water is below 2cm.
F4
The warning lights (WATER), (% HUMIDITY) and (ON) indicate at all times if the unit is
in good working order.
When the red warning light
(WATER)is ON the reservoir water level is
insufficient. See filling up procedure.
When the orange warning light
is ON (% HUMIDITY) the room humidity level is either the same or higher than
the Humidistat setting. If a higher level of humidity is required, turn the
humidistat clock wise to the required level. The green warning light comes ON
when the fan is operating, this also means the water level in the reservoir is
yet sufficient and the humidistat setting level is yet higher than the room
relative humidity level (%humidity).
U1
The humidistat keeps the humidity level of the room at the required level;
the evaporative pads and the fan start and stop automatically when the
humidistat
dictates it. The comfort zone is reached depending on the room temperature and
the hygrometry level. The higher humidity output is required if the room
temperature is raised; this phenomena is even more noticeable if the outside
temperature is lower. When the required humidity level is reached, the orange
warning light comes on.
(%
humidity)
U2 There are 2 fan speed available. In SPEED 2, the humidity level required
will be reached earlier. We recommend you begin in using speed 2 and when the
room humidity level is higher, the unit can be set on speed 1 to maintain the
best humidity level possible while a lower noise level.
U3 When the water level is
too low, the humidifier stops automatically and the red warning light comes on
(WATER).
Frequent
cleaning is necessary to maximize and extend the life of your humidifier.
Always disconnect the unit from the wall
socket before cleaning
and maintenance.
N1- Evaporative pads
The humidifier evaporative
pads have several functions. They are the most important parts of your
humidifier since they perform the following functions :
-
Air cleaning
-
Water filtration
-
Moisture Evaporation
It
is essential to keep the pads clean and replace them periodically (yearly)
depending on the amount of use, water hardness, local
air pollution. To exchange
the pads, remove the humidifier top cover. Grab the wheel axle
and remove the red plastic clips holding the outer foam-pad; remove the white
clips holding the circular foam-disk.
Clean
the foam pads with white vinegar or
de-scaling agent or replace with new ones if too old. Relocate in original
position. Fix foam pads in correct position with clips and washers.
N2 Water reservoir
Open the rear door and remove
the water reservoir while insuring not to damage the float. Clean all remaining
scale with scouring pad. Relocate water reservoir while insuring not to damage
the float. Replace back door in position (see P7 and P10, to open and close
back door).
N3 Cleaning inside and outside
Use a soft cloth with mild
soap to clean the outside and other inside parts with possible scale deposits
of your humidifier.
Adjustable humidistat
Power 45 Watts
Evapor. Capacity / 24h 60 Litres (at 21°C x
30% RH)
Air flow Speed 1 450 m3 / H
Speed 2 585 m3 / H
Reservoir capacity 34 Litres
Power consumption 45
Approvals CE
Dimensions (mm) 625
x 316 x 720
Net weight 18.6
Kg
Shipping dimensions 670 x 365 x 780
Shipping weight 20.6 Kg
Replacement pads ( set of 2 filters) PUR358
Automatic refill kit (option) WIN1610